| | SLO | ENG | Cookies and privacy

Bigger font | Smaller font

Show document Help

Title:Verifikacija merilnih metod za določanje analitov v serumu na biokemičnem analizatorju : magistrsko delo
Authors:ID Veranič, Simona (Author)
ID Kotnik, Petra (Mentor) More about this mentor... New window
ID Perva, Amra (Comentor)
ID Domajnko Ornik, Valerija (Comentor)
Files:.pdf MAG_Veranic_Simona_2026.pdf (2,74 MB)
MD5: 49E7811354D769904C35DFA203D1F817
 
Language:Slovenian
Work type:Master's thesis/paper
Typology:2.09 - Master's Thesis
Organization:FKKT - Faculty of Chemistry and Chemical Engineering
Abstract:V nalogi smo izvedli verifikacijo merilnih metod za izbrane biokemijske analite, ki so pomembni v diagnostiki anemij. To so železo, feritin, vitamin B12 in folati. Meritve smo izvajali na analizatorju Atellica CI Analyzer in rezultate primerjali z obstoječim analizatorjem Dimension EXL 200. Z uporabo kontrolnih materialov in vzorci preiskovancev smo ocenili natančnost, ponovljivost, točnost in primerljivost meritev. Statistična analiza je vključevala opisno statistiko, test normalnosti porazdelitev, statistične teste za primerjavo med skupinami meritev, korelacijsko analizo in Blant-Altmanovo metodo. Rezultati so pokazali dobro ujemanje med analizatorjema ter skladnost z zahtevami proizvajalca, kar potrjuje, da analizator Atellica zagotavlja zanesljive in klinično uporabne rezultate. Na podlagi ugotovitev je analizator primeren za uvedbo v rutinsko laboratorijsko diagnostiko.
Keywords:Verifikacija, statistika, natančnost, točnost, anemija.
Place of publishing:Maribor
Place of performance:Maribor
Publisher:[S. Veranič]
Year of publishing:2026
Number of pages:1 spletni vir (1 datoteka PDF (XI, 57 str.))
PID:20.500.12556/DKUM-97712 New window
UDC:577.087.1(043.2)
COBISS.SI-ID:277174787 New window
Publication date in DKUM:04.05.2026
Views:155
Downloads:11
Metadata:XML DC-XML DC-RDF
Categories:KTFMB - FKKT
:
Copy citation
  
Average score:(0 votes)
Your score:Voting is allowed only for logged in users.
Share:Bookmark and Share



Hover the mouse pointer over a document title to show the abstract or click on the title to get all document metadata.

Licences

License:CC BY-NC-ND 4.0, Creative Commons Attribution-NonCommercial-NoDerivatives 4.0 International
Link:http://creativecommons.org/licenses/by-nc-nd/4.0/
Description:The most restrictive Creative Commons license. This only allows people to download and share the work for no commercial gain and for no other purposes.
Licensing start date:06.04.2026

Secondary language

Language:English
Title:Verification of measurement methods for the determination of analytes in serum on a biochemical analyzer
Abstract:In this study, we verified measurement methods for selected biochemical analytes important in the diagnosis of anaemia, namely iron, ferritin, vitamin B12, and folates. Measurements were performed using the Atellica CI Analyzer, and the results were compared with those obtained from the existing Dimension EXL 200. Using control materials and patient samples, we evaluated the precision, repeatability, accuracy, and comparability of the measurements. Statistical analysis included descriptive statistics, tests of normality, statistical tests for comparison between measurement groups, correlation analysis, and the Bland-Altman method. The results showed good agreement between the two analysers and compliance with the manufacturer’s specifications, confirming that the Atellica analyser provides reliable and clinically applicable results. Based on these findings, the analyser is suitable for implementation in routine laboratory diagnostics.
Keywords:Verification, statistics, precison, accuracy, anemia.