Title:Določanje težkih kovin v negovalnih izdelkih
Authors:ID Flis, Tajda (Author)
ID Finšgar, Matjaž (Mentor) More about this mentor... New window
ID Rantaša, Matjaž (Comentor)
Files:.pdf MAG_Flis_Tajda_2026.pdf (2,42 MB)
MD5: 7689409739BB2809D9F16817BD4AEA03
 
Language:Slovenian
Work type:Master's thesis/paper
Typology:2.09 - Master's Thesis
Organization:FKKT - Faculty of Chemistry and Chemical Engineering
Abstract:V magistrskem delu je predstavljena raziskava vsebnosti izbranih elementov v različnih negovalnih izdelkih. S tehniko masne spektrometrije z induktivno sklopljeno plazmo (ICP-MS) smo določali vsebnost Al, As, Ba, Cd, Cr, Co, Cu, Fe, Ga, Mn, Mo, Ni, Pb, Sr, Sn, Ti, Tl in Zn v kremah za obraz, roke in za telo, v serumih za obraz, izdelkih za čiščenje obraza ter v kremah z zaščitnim faktorjem. Vzorce za elementno analizo smo pripravili z zaprtim mikrovalovnim kislinskim razklopom z uporabo HNO3, HCl in H2O2. Izvedli smo delno validacijo analizne metode ICP MS, pri kateri smo določali mejo zaznavnosti, mejo določljivosti, linearno koncentracijsko območje, točnost in natančnost. Pri primerjavi določenih vsebnosti z mejnimi vsebnostmi mednarodnih regulativ smo ugotovili, da je bila mejna vsebnost za As (2 μg/g) presežena v enem negovalnem izdelku, in sicer v kremi za obraz (KO9), kjer je bila določena vsebnost 3,50 ± 2,86 μg/g. V dveh izdelkih za čiščenje obraza (ČO7 z vsebnostjo 16,75 ± 1,09 μg/g in ČO8 z vsebnostjo 16,08 ± 0,02 μg/g) in eni kremi za obraz (KO1 z vsebnostjo 11,10 ± 0,33 μg/g) pa je bila presežena tudi mejna vsebnost za Ni, ki znaša 10 μg/g. Mejne vsebnosti za preostale težke kovine niso bile presežene. S statistično analizo smo primerjali vsebnosti As, Cr in Ni v negovalnih izdelkih nizkega, srednjega in visokega cenovnega razreda. Statistične razlike pri vsebnostih As in Ni nismo ugotovili. Pri Cr smo ugotovili statistično razliko v vsebnostih med negovalnimi izdelki nizkega in srednjega ter nizkega in visokega cenovnega razreda. Ugotovili smo tudi, da Al testerska embalaža ne vpliva na vsebnost Al v negovalnih izdelkih, saj ni bilo statističnih razlik med vsebnostjo Al v negovalnih izdelkih v Al testerski embalaži ter izdelkih v drugih vrstah embalaže.
Keywords:negovalni izdelki, težke kovine, kislinski razklop, induktivno sklopljena plazma z masno spektrometrijo, delna validacija analizne metode
Place of publishing:Maribor
Year of publishing:2026
PID:20.500.12556/DKUM-99299 New window
Publication date in DKUM:21.09.2026
Views:48
Downloads:5
Metadata:XML DC-XML DC-RDF
Categories:KTFMB - FKKT
:
Copy citation
  
Average score:(0 votes)
Your score:Voting is allowed only for logged in users.
Share:Bookmark and Share



Hover the mouse pointer over a document title to show the abstract or click on the title to get all document metadata.

Licences

License:CC BY-NC-ND 4.0, Creative Commons Attribution-NonCommercial-NoDerivatives 4.0 International
Link:http://creativecommons.org/licenses/by-nc-nd/4.0/
Description:The most restrictive Creative Commons license. This only allows people to download and share the work for no commercial gain and for no other purposes.
Licensing start date:11.08.2026

Secondary language

Language:English
Title:Determination of heavy metals in care products
Abstract:This master’s thesis presents a study of the content of selected elements in various personal care products. Inductively coupled plasma mass spectrometry (ICP-MS) was used to determine the content of Al, As, Ba, Cd, Cr, Co, Cu, Fe, Ga, Mn, Mo, Ni, Pb, Sr, Sn, Ti, Tl, and Zn in face, hand, and body creams, facial serums, facial cleansing products, and sunscreens. Samples for elemental analysis were prepared by closed-vessel microwave assisted acid digestion using a mixture of HNO3, HCl, and H2O2. A partial validation of the ICP-MS method was performed by determining the limit of detection, limit of quantification, linear concentration range, accuracy, and precision. When comparing the results to the limit values set by international regulations, we found that the limit value for As (2 μg/g) was exceeded in one personal care product, i.e. in a face cream (KO9) with 3.50 ± 2.86 μg/g. In two facial cleansing products (ČO7 with 16.75 ± 1.09 μg/g and ČO8 with 16.08 ± 0.02 μg/g) and one face cream (KO1 with 11.10 ± 0.33 μg/g) the limit value of 10 μg/g for Ni was also exceeded. The limit values for other heavy metals were not exceeded in any sample. We used statistical analysis to compare the content of As, Cr, and Ni in personal care products in the low-, medium-, and high-price ranges. We found no statistical differences for As and Ni content. Statistical difference was observed in the Cr content between low- and medium-priced personal care products, as well as between low- and high-priced personal care products. Al packaging did not affect the Al content, as no statistical differences were observed between the Al content in personal care products from Al packaging and those in other types of packaging.
Keywords:care products, heavy metals, acid digestion, inductively coupled plasma mass spectrometry, partial validation of analytical method


Comments

Leave comment

You must log in to leave a comment.

Comments (0)
0 - 0 / 0
 
There are no comments!

Back
Logos of partners University of Maribor University of Ljubljana University of Primorska University of Nova Gorica