Title:Tehnološka in stroškovna analiza uvedbe sesalnega akumulatorja v hladilni sistem
Authors:ID Jug, Aleš (Author)
ID Čuš, Franc (Mentor) More about this mentor... New window
Files:.pdf UN_Jug_Ales_2015.pdf (2,62 MB)
MD5: 4809D72AB05D0153AEBE50E5B328B238
 
Language:Slovenian
Work type:Bachelor thesis/paper
Typology:2.11 - Undergraduate Thesis
Organization:FS - Faculty of Mechanical Engineering
Abstract:Sesalni akumulator je ključni element raziskave v diplomskem delu. Element se nahaja v hladilnem sistemu za uparjalnikom. Obravnavan problem zajema zamenjavo bakrenega akumulatorja z drugim, ki bo cenovno ugodnejši in bo prav tako izpolnjeval enake tehnične karakteristike kot predhodna izvedba. Problem bakrenega akumulatorja se pojavi pri spoju z aluminijasto cevjo, kjer zaradi neustrezne obdelave površine na spoju prihaja do puščanja. Pri iskanju najugodnejše rešitve sem si pomagal s tabelo virov. V okviru eksperimentalnega dela so bila izvedena mehanska testiranja, testiranja notranje vlage ter nečistoč, slana komora in analiza poroznosti spoja. Ugotoviti je bilo potrebno tudi ustrezen način spajanja ter izvesti stroškovno analizo. Izmed vseh rešitev se je kot najprimernejši izkazal aluminijast akumulator, ki ga v sistem spojimo s postopkom lotanja. Zamenjava akumulatorja omogoča večje prihranke ter zmanjšanje zastojev v proizvodnem procesu.
Keywords:hladilni sistem, zamenjava sesalnega akumulatorja, tehnologija spajanja, izbira ustreznega materiala, mehansko testiranje, izračun stroškov, ovrednotenje izbrane rešitve.
Place of publishing:Maribor
Publisher:[A. Jug]
Year of publishing:2015
PID:20.500.12556/DKUM-54224 New window
UDC:[658.511:62-71]+657.478(043.2)
COBISS.SI-ID:19140374 New window
NUK URN:URN:SI:UM:DK:QQK7KPIU
Publication date in DKUM:27.10.2015
Views:1574
Downloads:146
Metadata:XML DC-XML DC-RDF
Categories:KTFMB - FS
:
Copy citation
  
Average score:(0 votes)
Your score:Voting is allowed only for logged in users.
Share:Bookmark and Share



Hover the mouse pointer over a document title to show the abstract or click on the title to get all document metadata.

Secondary language

Language:English
Title:Tecnological and cost analysis of introducing the suction accumulator in the cooling system
Abstract:Suction accumulator is the key element of the research in the thesis. The element is located in the cooling system behind the evaporator. This issue deals with the replacement of the copper suction accumulator with another, which will be cheaper and will also meet the same characteristics as the previous one. The problem with the copper accumulator occurs in the junction between the accumulator and the aluminium tube. Due to the inadequate treatment of the surface there can be some leakage in the junction. In the search for the best solution I have helped myself with the table of the resources. Experimental work included mechanical testing, testing of internal moisture and impurities, salt chamber testing and analysis of porosity in the joint. I also had to find a suitable way of fusing and carry out a cost analysis. Aluminium accumulator proved to be the most suitable solution and can be added in the cooling system with the process of soldering. The replacement of the suction accumulator is economical and reduces congestions in the manufacturing process.
Keywords:cooling system, replacement of the suction accumulator, merge technology, selection of appropriate materials, mechanical testing, calculation of expenses, evaluation of selected solution.